arnoflex 7 UF COAXIAL CABLE / 50 Ω

The arnoflex 7 UF cable is suitable for a frequency range up to 3 GHz. The RF line is flexible and recommended for wireless communication applications.
The good attenuation values are achieved by a low-loss PE dielectric with an air content of more than 50%, as well as by the inner conductor and the double shielding from pure copper.

Application fields: News and wireless communication technology: it is extremely flexible, with low attenuation and stray radiation resistant.

arnoflex 7 UF: (Sheath colour: black) 50 Ω;
Temperature range from -30°C up to +80°C

arnoflex 7 UF Coaxial cable Material diameter
Inner conductor Copper stranded wire Ø 1.85 mm
Dielectric Foamed PE Ø 5.00 mm
Cable screen Copper foil , Copper braiding Ø 5.60 mm
Cable sheath PVC, black Ø 7.30 mm

Cable comparison

Cable picture
arnoflex 7 UF coaxial cable, halogen-free
Aircell 7 coaxial cable
Aircell 7 Heatex
HIGHFLEXX 7 coaxial cable
Description arnoflex 7 UF coaxial cable, halogen-free Aircell 7 coaxial cable Aircell 7 Heatex HIGHFLEXX 7 coaxial cable
Article number 050284 050117 050318 050224
Price [ab_€/m] 0,97 EUR 2,59 EUR 3,10 EUR 2,75 EUR
Data sheet [pdf] 146KB 198KB 201KB 798KB
Cable screen type
Double shielded
Double shielded
Double shielded
Double shielded
Manufacturer
arnotec GmbH
SSB
SSB
Messi & Paoloni
Technical data - Structure
Outer diameter
Ø 7.3 mm
Ø 7.3 mm
Ø 7.3 mm
Ø 7.3 mm
Sheath material
PVC
PVC
FRNC / LSNH
PVC
Sheath colour
black
black
black
black
Diameter dielectric
Ø 5 mm
Ø 5 mm
Ø 5 mm
Ø 5 mm
Dielectric
PE fm
PE fm
PE fm
PE fm
Inner conductor
Ø 1.85 mm
Ø 1.85 mm
Ø 1.9 mm
Ø 1.9 mm
7 x Ø 0.65 mm
19 x Ø 0.38 mm
19 x Ø 0.38 mm
19 x Ø 0.38 mm
Inner conductor
Copper stranded wire
Copper stranded wire
Copper stranded wire
Copper stranded wire
Electrical values
Impedance
50 Ω
50 Ω
50 Ω
50 Ω
Max. frequency [Ghz]
3
6
6
6
Capacity [p/m]
80
78
78
75
Shielding factor [dB/m]
80
90
90
105
Max. Voltage [V]
8000
8000
Halogen-free
Non-magnetic
Attenuation values at different frequencies
Attenuation at 400MHz [dB/m]
0.14
0.13
0.13
0.12
Attenuation at 1000MHz [dB/m]
0.23
0.2
0.2
0.19
Attenuation at 2000MHz [dB/m]
0.35
0.3
0.3
0.34
Other parameters
Temperature [max.°C]
70
85
80
60
[min.°C]
-30
-55
-40
-40
Weight [kg/m]
0.073
0.07
0.073
0.07
Further information
Information Link Link Link Link
Cable and cable ready made Now assembled Now assembled Now assembled Now assembled